• Modernization
  • Spare parts
  • Fast delivery

Door interlock CLFMO-L-X15(u35°).5.P With faulty closure device, motorized

Flattest device with motorized actuation

The CL(F)MO has a low overall height and is unlocked with an integrated electric motor. The energy-saving motor has a high starting power and operates almost silently.

Article no.: 1200521
Available on order
  • Specification
    Actuation Motorized
    Connection Screw terminal max. 1.5 mm², cable entry M20x1.5 with clamping gland
    Bevel below 35 °
    Distance door edge 15 mm
    Width 66 mm
    Depth 33.5 mm
    Pull-in / holding current 0.85 / 0.20 A
    Supply voltage 24 V DC (-10 % / +25 %) regulated
    Length 287.5 mm
    Ambient air temperature - 10 - + 45 °C
    Faulty closure device Yes
    Protection class IP40
    Operation Left-hand
    Weight 0.95 - 1.10 kg
    Other See more specifications under files
  • Description

    General

    • Metal housing with high stability
    • Silent due to buffers in both directions
    • Maintenance-free by permanent lubrication with high quality lubricants
    • Constrained faulty closure at CLFMO for use in passenger lifts
    • Contacts with fine silver plating for a reliable function even at low voltages and currents
    • Extensive range of accessories

    Special features

    • Integrated actuation by maintenance-free, low-noise three-phase motor and decelerated dropping of the bolt
    • Patent protected by Gbm DE 20 2015 105 331 and by patent EP 3 153 454 B1, validated in DE / FR / IT / ES
    • Low pull-in current (< 1 A at 24 V)
    • Automatic switching over to reduced holding current (0.2 A) saving energy
    • Safe unlocking by position monitoring even if the bolt is temporarily blocked (incorrect operation)
    • Status display by coloured LED’s
    • Symmetrical fixing dimensions and centrically arranged latch bolt
    • Low construction height
    • Reduced bolt stroke
    • Integrated auxiliary switch (standard)

      Optional
    • Monitoring of the base side emergency release with positive opening safety switch (EN 81-21)
    • Same position of the emergency release triangle also indirect with monitoring
    • Lever for self-liberation (manual operation) from the pit and preparation for external cable pull always existing