• Modernization
  • Spare parts
  • Fast delivery

Door interlock DL2MO-L-X15(u45°).14.90/01.P Without faulty closure device, motorized

With the door interlock DL(F)2MO shaft doors are unlocked and locked silently.
This is ensured by the electric motor integrated in the DL(F)2MO which can tighten the bolt reliably, silently and with high force.
Door interlocks of DL(F)2MO type are installed in the door post above the door.

Article no.: 1200543
Available on order
  • Specification
    Actuation Motorized
    Connection Screw terminal max. 2.5 mm², cable entry Ø23 mm with rubber gommet
    Bevel below 45 °
    Distance door edge 15 mm
    Width 80 mm
    C/C Mounting holes 370 mm
    Depth 40 mm
    Pull-in / holding current 0.80 / 0.15 A
    Supply voltage 24 V DC (-15 % / +25 %) regulated
    Length 390 mm
    Ambient air temperature - 10 - + 45 °C
    Faulty closure device No
    Protection class IP40
    Operation Left-hand
    Weight 1.50 - 1.85 kg
    Other See more specifications under files
  • Description

    General

    • Metal housing with high stability
    • Transparent cover for optimal function control
    • Silent due to buffers in both directions
    • Maintenance-free by permanent lubrication with high quality lubricants (down to -30 °C)
    • Oiled felt rings at the latch bolts for lubrication as well as for sealing against dust and dirt (at X-dimension ≥ 10 mm)
    • Contacts with solid fine silver plating for a reliable function, also at low voltages and currents
    • Auxiliary switch with one contact
    • Extensive range of accessories

    Special features

    • Integrated actuation by maintenance-free, low-noise three-phase motor and decelerated dropping of the bolts
    • Patent protected by Gbm DE 20 2015 105 331 and by patent EP 3 153 454 B1, validated in DE / FR / IT / ES
    • High starting power
    • Low pull-in current (< 1 A at 24 V)
    • Automatic switching over to reduced holding current (< 0.2 A), energy-saving
    • Safe unlocking by position monitoring even if the bolts are temporarily blocked (incorrect operation)
    • Status display by coloured LED’s
    • Terminal block with all electrical connections
    • Liberation from the pit by cover side triangle or optional pull lever for manual operation
    • Connection for bowden cable or cable pull for unlocking available (.14)
    • e.g.
    • Application 1: unlocking from the pit ladder (< 1.80 m according to EN 81-20)
    • Application 2: offset emergency release triangle (< 2 m according to EN 81-20)

     

  • Files