- Light curtain LUX series
- 194 crossed beams
- Red-green signaling TX RX
- Power supply 230VAC
- Extension cable pair 2.5m
- EN 81-20 & EN 81-70
- Total height 2000mm
- Dynamic installation only
Copy and paste the link into a web browser to see a video:
https://www.youtube.com/shorts/032SEp564m4
-
Specification
Number of elements 40 pc(s) Number of beams 194 pc(s) Length 2000 mm Width 26 mm Height 10.60 mm Cable length 2.5 m Supply voltage 85-265VAC, 50/60HZ Max current consumtion <=4W or 100mA@24VDC Ambient air temperature - 20 ... + 65 °C Relay output Relay 1NC, 2NO Relay output 1A@120VAC or 1A@24VDC Response time 100 ms Range 0 - 4 m Prtoctive height 20 - 1800 mm Protection class control unit IP31 Protection class opto edges IP54 Other See files -
Description
1. DOOR OPENING SEQUENCE:
1.1 When the door distance is < 100mm, the LED strip is not lit.
1.2 When the doors are opening, and the gap is between 100mm to 500mm, the LED
strip will emit a SOLID RED light.
1.3 When the door distance is > 500mm, the LED strip will emit a FLASHING GREEN
light.
1.4 After the doors have been fully opened for 4 seconds, the FLASHING GREEN
light will switch to a SOLID GREEN light.2. DOOR CLOSING SEQUENCE:
2.1 When the doors start to close, the LED strip will emit a FLASHING RED light.
2.2 When the doors are closing, and gap is between 400mm to 100mm, the FLASHING
RED light will switch to a SOLID RED light.
2.3 After the doors are fully closed for 4 seconds, the LED strip will turn off. - Files